The best solutions for large-sized modules in future? Hear what R&D “veterans” say
Figure 2 Design of a typical 1/3-cutting MBB (9BB–14BB) 210-cell
Secondly, in terms of layout design, to achieve successful circuit protection, the number of bypass diodes will be significantly different—for the half-cutting series connection-only solution and the 1/4-cutting solution, five bypass diodes are needed, which add to the manufacture difficulty and the width of the module layout; for the traditional half-cutting and series and parallel connection architecture and the 1/3-cutting solution, three bypass diodes are used and the manufacture difficulty is lower; for the 1/5-cutting architecture, similar to the layout of the currently mainstream shingled modules in the market, two diodes are used, which increases the number of cells to be protected by each bypass diode. In terms of hotspot risks, whether hotspots will appear is determined by the reversed bias voltage working on the cell in times of reverse bias; the density distribution of the forward current and leakage current produced in the hot-spotted cell also plays a role. Multi-piece small cells, such as typical shingling modules wherein the number of cells in series and parallel connection per bypass diode is up to 34, have functioned well outdoors. Hence, for multi-piece modules, as long as the leakage current center induced during splitting operation is effectively limited, taking into account the safety factor, the modules would have little chance of suffering hotspots when the number of cells in parallel connection per diode is smaller than or equal to 30. In terms of safety performance of junction boxes, lower-current design for both the modules and the system can minimize safety risks associated with the switching on or short circuiting of the bypass diode. For modules whose current is far beyond that of the mainstream 158.75 mm or 166 mm modules, the safety risks will increase exponentially. These risks can be eliminated by, say, improving the performance of junction boxes and the system-side cables. However, this would mean a significant cost increase, which contradicts the general trend toward fair prices. If our 1/3-cutting 210-modules are used, on the contrary, the output current increase, relative to output current of mainstream modules, can be limited to around 15%. This way, you will expect high-reliability service from the junction box simply with minimal design optimization. In terms of limitation of input current from the DC side, by utilizing the surplus of inverter input, the maximum output current of the modules so far should be limited to 15 A and the maximum current of the front side should also be limited to around 12.5 A. The maximum operating current of 1/3-cutting 210-module is less than 12A. Furthermore, as cell modules become more efficient and faster, inverter manufacturers will also increase the limitation on current input from the DC side. As analyzed above, Trina Solar's R&D team believes that the 1/3-cutting plus MBB technique will help 210-modules to achieve higher power with low manufacture and hotspot risks, high junction box safety, and no chance of losing power generation associated with inverter current limitation. It will be on top of all other 210-module solutions within the next three to five years to come.